ELGAS-2 (CP II)

ELGAS-2 (CP II)

ELGAS-2 (CP II) communication protocol

Supported device types and versions 
Communication line configuration
Communication station configuration
I/O tag configuration
Literature
Changes and modifications
Document revisions

Supported device types and versions


The protocol supports the communication with ELCOR-2, microELCOR-2, and ELCORLite devices (made by the ELGAS company ) that recalculate a gas quantity.

Communication line configuration


The asynchronous transmission parameters are set according to the setting of a specific device.

Communication station configuration


  • Communication protocol: Elcor ELGAS-2 (CP II).

  • Station address:

    • Node address: value in the range of 0 to 65535.

    • Address: meter address, a value in the range of 0 to 255.

    • If both addresses are 0, the device must answer obligatorily.

Password for reading: maximum of 6 characters is allowed if the password is set in the device (ELCOR-2 only).

Station protocol parameters

Configuration dialog box  - tab „Parameters".
They influence some optional parameters of the protocol. Following station protocol parameters can be set:

Table 1

Full name

Meaning

Unit

Default value

Device Type

Selection of device type.

ELCOR-2 or microELCOR-2

ELCOR-2

Retry Count

The delay between request retries in case of a communication failure.

 

3

Wait First Timeout

Delay after sending the request before reading the response.

ms

100 ms

Wait Timeout

Delay between response readings until it is completed.

ms

100 ms

Max. Wait Retry

Retry count of response reading until it is completed.

 

30

Static Data Read Period

Static - configuration data read period (microELCOR-2 only).

min

60 min

Hourly Archive Periodic Reading

A period for the reading of hourly archives (0-60 min). Value 0 disables the reading.

min

0 min

Wake Up Sequence Length

Length of 'wake-up' data sequence, which is sent before the request after a longer communication pause.

0 .. 50 bytes

25 bytes

Wake Up Each Query

Insert 'wake-up' data sequence before each request.

YES/NO

NO

Wake Up Character

Form 'wake-up' data sequence from the specified characters.

0 .. 255

255

Group Source Address

Group source address (address of the D2000 KOM process).

0 .. 65535

0

Source Address

Source address (address of the D2000 KOM process).

0 .. 255

0

Full Debug

A high level of communication tracking, the received values of I/O tags and other debug information is shown.

YES/NO

NO

I/O tag configuration


Possible value types of I/O tags: Di, Ai, Ci, TxtI, TiA.

The ELCOR-2 device

Table 2 contains the list of main parameters of the device.
Tables 3 to 8 contains the list of variable configuration and informative data according to the parameter type. DESC(ind) parameter represents the common data of all parameters. It describes the quantity. The current value of quantity can be acquired by the configuration of the I/O tag with numerical address - index ind (number from 1 and higher). To find out the technical units - configure text of I/O tag with address UNIT(ind).

Table 2 - Device parameters - Main device parameters

Object description

Value type

Address

Units

The serial number of the device

Ci, TxtI

SN

 

Referential temperature

Ai

TB

°C

Referential pressure

Ai

PB

kPa

Firmware version

TxtI

FW

 

Station name

TxtI

DESC

 

CO2 concentration

Ai

TAB(0)

%

N2 concentration

Ai

TAB(1)

%

Heat of combustion

Ai

TAB(2)

MJ/m3

Relative density

Ai

TAB(3)

 

H2 concentration

Ai

TAB(4)

%

H2S concentration

Ai

TAB(5)

%

He concentration

Ai

TAB(6)

%